Industrial Testing Gauges Suppliers In India
Industrial Testing Gauges Suppliers In Coimbatore
Product Details:
| Minimum Order Quantity | 1 Piece |
| Model Name/Number | GI 1312 |
| Product Type | K Type |
| Temperature Range | : -200~1370C |
| Usage/Application | Industrial |
| Material | Plastic |
| Power Source | Battery |
| Diameter | 158x75x41lmm |
| Color | Yellow |
Thermocouple K-Type Probe Thermometer Dual Channel , K Type Digital Pyrometers Thermocouple Industrial
Specification
Name: Dual Channel Thermometer
Display: LCD display
Temperature Range: -200~1370C(-328.0F ~ 2498.0F)
Resolution: 0.1'C/0.1F
Accuracy: 0.1%+0.4°
Storage Environment: -10 ~ 50C(-14 ~ 122F),Humidity <80%
Working Environment: -10 ~ 50"C(-14 ~ 122F),0 ~ 70%Rh
Dimensions: 158x75x41lmm
Weight: 257g(Battery not included)
Power: 4*1.5V batteries
ORIGIN: GABY INSTRUMENTSAdditional Information:
Product Details:
| Minimum Order Quantity | 1 Piece |
| Detector Type | Portable Multi Gas |
| Power Source | Battery |
| Model | GIHT 609 |
| Display Type | Digital |
| Measuring Range | 50-1000ppm |
| Dimensions | Size: 142X58X28mm |
COMBUSTIBLE GAS DETECTOR
Portable Gas Leak Detector
Specification
Display: LCD
Product name: Gas Leak Detector
Measuring gas type: More than 12 kinds
1, Methane-CH4,
2, Propane-CH2C12,
3, Is Ethane-C6H14,
4, Ethane-C2H6,
5, CO- The Gas/Oxidation of Carbon,
6, Benzene-C6H6,
7, N-Butane -C4H10,
8, Ethanol – C2H5OH,
9, Gasoline,
10, Epoxy ethane -C2H4O,
11, Ethylene – C2H4,
12, Acetylene – C2H2,
Combustible gas Range: 50-1000ppm
Temperature Range: -20~60°C
Humidity Range: 0.0%~99.9% RH
Size: 142X58X28mm
Additional Information:
Product Details:
| Minimum Order Quantity | 1 Piece |
| Type Of Tachometer | Digital Tachometer |
| Brand | Gaby Instruments |
| Usage/Application | Industrial |
| Material | Plastic |
| Resolution | 0.05% |
| Power Supply | Battery |
| Color | Black |
| Accuracy | 0.05% |
DIGITAL LASER TACHOMETER CONTACT & NON-CONTACT TYPE
Specifications:
Ø Measurement
Ø Photo Tach (2.5 ~ 99,999 RPM),
Ø Contact Tach (0.5 ~ 19,999 RPM),
Ø Surface Speed (0.05 ~ 1,999.9m/min , 0.2~ 6,560ft/min)
Ø Auto Ranging,
Ø Detecting distance - 500mm or 20inch
Ø Accuracy - ±(0.05% +1digit).
Ø Dual Function unit - both Contact and Non-contact capabilities
Ø Provides fast and accurate RPM (revolutions per min) measurements of rotating objects
Ø Internal memory recalls maximum, minimum values as well as last value stored
Additional Information:
Product Details:
| Minimum Order Quantity | 1 Piece |
| Power Supply Type | Battery |
| Power Source | Battery |
| Display Type | LCD |
| Power Supply | Battery |
| Connectivity Type | USB |
| Parameters Measured | Temperature and Humidity |
| Parameter To Be Monitored | Humidity |
| Number Of Channels | 1 channel |
| Type Of Data Logger | USB |
| Input Type | Universal |
| Mounting Type | Portable |
| Usage Type | Reusable |
| Export Of Data | Excel |
| Interface | USB |
| Memory | 34560 |
| No. Of Channels | Single Channel |
| Minimum Order Quantity | 11 |
Specification
Temperature Range: -40℃~85℃
Humidity Range: 0%~100%RH
Data Capacity: 34560
Humidity Accuracy: ±3% (10%~90%), ±5%(other)
Temperature Accuracy: ±0.3℃ (0~60℃), ±0.6℃(other)
Resolution: 0.1%RH typically, 0.1℃
Protection Level: IP65
Battery Lifetime: More than 2 years (Normal temperature 25℃)
Additional Information:
Product Details:
| Battery voltage | 12 V 24 V |
| Voltage | 12 V 24 V |
| Battery type | Lead acid |
| Measurement | Voltage |
| Display type | LCD |
| Data interface | No interface |
| CCA range | 40 to 600 A |
| Model Name/Number | GI330 |
| Weight | 250 gm |
| Accuracy | 5% |
| Power source | Battery |
| Led Color | 16-bit colorful screen |
| Testing Time | immediate |
| Operating Temperature | 0 - 60 deg c |
Product name: 12V/24V battery analyser
Range of application: 12V/24V automobile Lead-acid batteries
Function: Test Capacity Voltage Current
Screen material: 16-bit colorful screen
Battery capacity range: 3AH-220AH
Voltage test range: 9V-35V
Sheath material: TPU
Accuracy: 5%
Waveform: yes
Product Details:
| Output Signal | RS485 |
| Mounting Type | Wall Mount |
| Humidity Range | 5%RH ~ 95%RH |
| Temperature Range | -40℃ ~ 85℃ |
| Measured Parameters | RH + Temp |
| Accuracy RH | ±2% RH |
| Display | No Display |
TEMPERATURE HUMIDITY TRANSMITTER RS485
Application
Greenhouse Warehouse Intelligent Building Industry HVAC Communication Room
Specification
Temperature Range: -40℃ ~ 85℃ Accuracy: ±0.3°C (0 ~ 60°C), ±0.5°C (other)
Humidity Range: 5%RH ~ 95%RH (non-condensed)
Humidity Accuracy: ±2% (10% ~ 90%) RH, ±4% (other)RH
Output: RS485
ORIGIN: Gaby Instruments TZONEProduct Details:
| Parameter To Be Monitored | Temperature and Humidity |
| Connectivity Type | USB |
| Display | LCD |
| Type Of Data Logger | Multi-Use |
| Mounting Type | Portable |
| Temperature Range | -30 - 70 degree c |
| Memory | 32000 readings |
| Interface | USB 2.0 |
Temp-Humidity USB DATA LOGGER
Specification
Temperature Range: -30℃ ~ 85℃ Resolution: 0.1°C Accuracy: ± 0.5°C (-20 ~ +40°C),
Humidity Range: 5% ~ 95% RH Resolution: 0.1% RH Accuracy: ±5% RH
Memory Capacity: 32000 data points Protection Level: IP54
Battery Lifetime: 2 years Dimension: 89*36*16 mm
ORIGIN: TZONEProduct Details:
| Output Signal | RS485 |
| Mounting Type | Wall Mount |
| Humidity Range | 5% to 99% RH |
| Temperature Range | -40℃ to 125℃ |
| Measured Parameters | RH + Temp |
| Accuracy RH | 0.1%RH |
| Display | LCD |
TEMPERATURE HUMIDITY TRANSMITTER RS485
Application: Generally Used in Indoor Clean Environment, Such as: HVAC, Building Automation, Laboratory, Hospital, Library, Storage and Production Facilities in the Pharmaceutical, Paper, Food and Electronics Industries.
Features: Low Power Consumption, Fully Calibrated, High Precision and Good Consistency, Long-Term Stability, Low Drift, Humidity Full Range Temperature Compensation, Standard Modbus-RTU Protocol, Strong Interface Defense Capability and Stable Communication
Specification
Sensing Element: SHT30
Temperature Range: -40℃ to 125℃ Resolution: 0.1℃
Accuracy: ±0.3℃ (0~60℃); ±0.5°C for Other Range
Humidity Range: 5% to 99% RH Resolution: 0.1%RH
Accuracy: ±2%(10%~90%RH); ±4% for Other Range
Output: RS485 port, standard Modbus rtu Transmission Rate: Optional 4800bps / 9600bps
Environment: -40~85℃/ 5~95% RH (Non-condensing) Supply Voltage: DC 5~36V