Online Water Chlorine Controller
Product Details:
Range | 0 to 10 mg/L |
Resolution | 0.001 |
Accuracy | 2 % |
Brand | GABY INSTRUMENTS |
Model Name/Number | GI900 |
Warranty | 1 yr |
Country of Origin | Made in India |
Chlorine Controller with electrode
We Labcare Scinetific is Importer and Supplier of chlorine controllers in Coimbatore, Kerala, Tirupur, Pollachi, Erode, Salem, Chennai, Karur, Banglore, Idukki, Cochin, Trishur, Ernakulam, Trivandrum, Madurai, Tirunelveli , all over india and world wide
Measuring range:0.00...20.00mg/L
Temperature compensation mode:Automatic / manual
Resolving power:0.1%
Temperature measurement range:-25℃...130℃
Current signal output:4...20mA(Adjustable)
Current precision:1%FS
Relay:5A 250VAC/5A 30VDC
Data interface:RS485(MODBUS-RTU)
Working power supply:220VAC Or 24VDC
Working temperature:0...60℃
Working humidity:relative humidity<90%
Protection grade:IP65
Installation method:Dial installation
Fixed mode:Double clip fixing
Shape size:144*144*120mm
Aperture size:138*138mm
Weight:0.6kg
Feature
Calibration and setting can set cryptoguard respectively.
LCD liquid crystal display with backlight.
Use keyboard to set parameters.
High stability , high accuracy.
Wide measure range.
Temperature compensation.
Multiple output (relay,0/4-20mA).
Supper anti-interference design can be used for strong interference with field operations and
anti-electromagnetic interference.
The built-in memory chip ensures that the parameters and calibration data are not lost when shut
down or off normally.
Can automatically detect the temperature probe and enter the automatic temperature
compensation program.
Product Details:
Minimum Order Quantity | 1 Piece |
Usage/Application | Industrial |
Range | 0 to 10 mg/L |
Resolution | 0.001 |
Accuracy | 2 % |
Brand | GABY INSTRUMENTS |
Model Name/Number | GI800 |
Warranty | 1 Year |
Country of Origin | Made in India |
Online Chlorine Controller with Electrode
Immertion Type
We Labcare Scinetific is Importer and Supplier of chlorine controller in Coimbatore, Kerala, Tirupur, Pollachi, Erode, Salem, Chennai, Karur, Banglore, Idukki, Cochin, Trishur, Ernakulam, Trivandrum, Madurai, Tirunelveli , all over india and world wide
Measuring range Residual chlorine : 0~20.00mg/L; Resolution: 0.01mg/L
Accuracy residual chlorine ±2% or ±0.035mg/L take the bigger
Sample temperature 0~60℃, 0.6MPa
Sample flow rate 200~250mL/min
Stability ±0.2(mg/L)/24
Minimum detection limit 0.01mg / L automatically adjustable
Electronic unit repeatability error ±0.2 mg/L
Display LCD display, English operation interface
Isolated current output 4~20 mA (load <750Ω)
Output current error ≤±1%FS
High and low alarm relays AC220V, 7A; hysteresis 0- 5.00mg / L, arbitrary regulation
Interface RS485 ,Compatible with standard MODBUS-RTU
Power supply 100-240VAC or 24VDC
Protection grade IP65
Power ≤5W
Temperature Sensor NTC22K
TEMP.Compensation Automatic/Manual
Installation Panel Mounting
Dimension 96*96*138mm(L*W*D)
Hole size 91*91mm
Working conditions: ambient temperature: 0-60°C; relative humidity≤85%
Feature
Calibration and setting can set cryptoguard respectively.
LCD liquid crystal display with backlight.
Use keyboard to set parameters.
High stability , high accuracy.
Wide measure range.
Temperature compensation.
Multiple output (relay,0/4-20mA).
Supper anti-interference design can be used for strong interference with field operations and
anti-electromagnetic interference.
The built-in memory chip ensures that the parameters and calibration data are not lost when shut
down or off normally.
Can automatically detect the temperature probe and enter the automatic temperature
compensation program